Megatro Power Distrubution Steel 230kv Steel Pylon Tower

Product Details
Usage: Crossing Tower, Tension Tower, Terminal Tower
Conductor Circuit: Single Circuit
Certification: ISO
Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 14001, OHSAS/ OHSMS 18001
Find Similar Products

Basic Info.

Model NO.
MGP-PT230
Materials
Steel
Standard
Nonstandard
Style
Independence Tower
Structure
as Per Drawings and Client Requirement
Accessories 1
Power Fitting
Accessories 2
Conductor and Cable
Accessories 3
Earth Wire and Opgw
Accessories 4
Insulator
Accessories 5
Aviation Light
Accessories 6
Tower Earthing Kits and Template
Accessories 7
Razor Steel
Accessories 8
Anti-Climbing Devices
Accessories 9
Anti-Bird Devices
Accessories 10
Dangerous Plate
Accessories 11
Signal Plate
Accessories 12
Circuit and Phase Plate
Accessories 13
Fall Arrestor
Other Services1
Installation Guide
Other Services2
Engineering Cost and Project Budget
Transport Package
Export Standard Package
Specification
as per drawings and client requirement
Trademark
MEGATRO
Origin
Shandong, China
HS Code
73082000
Production Capacity
80000 Tons/Year

Product Description

MEGATRO 230KV double circuit steel tower MGP-DS-STR09
This photo refers to our 230kv double circuit transmission tower DS STR01, two earth wire at top tower peak, this type tower design and supplied to most of Africa and Asian countries and regions, it is double circuit power transmission line towers.

Their technical data as follow:
1 power voltage: 230KV
2 conductor and wires
  conductor OPGW Ground lead wire
Size and type 1*795MCM ACSR/AS "Condor"
Aluminum clad steel wire core type, single conductor/phase
OPGW shall be 36 fibers and aluminum clad  steel wire OPGW should be OHGW/AS aluminum clad steel wire, 7 no. 6 AWG TYPE
Stranding 54/7 - 7
Outside diameter 27.73mm 15mm(approx.) 9.25mm
Cross-sectional area 454.78mm2 - 51.10mm2
Weight 1.46kg/m 0.6300kg/m 0.406kg/m
Breaking strength 12600kg 10197kg 1929kg(approx)

3 horizontal tension limits (percent of conductor breaking strength)
MATERIAL Unloaded loaded
Initial (15ºC) Final (15ºC) Final (15ºC)
conductor 33.33 25 40
OPGW/OHGW 30 15 26

4 Conductor clearance, values strictly minimum
Crossing over @ 150ºC, no wind, final sag
Railroad tracks                             12.57m
Public streets and highways                  12.57m
Rural road                                  12.57m
Areas accessible to pedestrian only            11.05m
All other types of obstruction                  in accordance with PEC, Part II latest edition

5 Tower design criteria
Footing resistance                            5ohms or less
Design wind velocity                          zone 1-300kph
Ultimate design loadings                      refer to loading diagram of each tower


6 design standard
6.1 Automatic calculation of tower dead, ice, and wind loads as well as drag coefficients according to:
ASCE 74‐1991, 2009
o NESC 2002, 2007, 2012, 2017
o IEC 60826:2003, 2017
o IS 802 : 1995, 2015
o ISEC‐NCR‐83
o EN50341‐1:2001 and 2012 (CENELEC)
o EN50341‐3‐2:2001 (Belgium NNA)
o EN50341‐3‐9:2001, EN50341‐2‐9:2015, 2017 (UK NNA)
o EN50341‐3‐17:2001 (Portugal NNA)
o EN50341‐2‐22:2016 (Poland NNA)
o AS/NZS 7000:2010, 2016
o ESAA C(b)1‐2003 (Austalia)
o TPNZ (New Zealand)
o REE (Spain)
o SP 16.13330.2011 (SNiP Russia)
Minimization of problems caused by unstable joints and mechanisms
Automatic bandwidth minimization and ability to solve large problems
Design checks according to (PLS can add strength checks for other standards):
o ASCE 10
o AS 3995 (Australian Standard 3995)
o BS 8100 (British Standard 8100)
oEN50341-1 2001 and 2012 (CENELEC, both empirical and analytical methods are available)
o EN50341‐2‐9:2015, 2017 (UK NNA)
o ECCS 1985
o NGT‐ECCS
o PN‐90/B‐03200
o EN50341‐2‐22:2016 (Poland NNA)
o SP 16.13330.2011 (SNiP Russia)
o EDF/RTE Resal
o IS 802 (India Standard 802)

6.2  Analysis and Design Calculations
The strength of the members was determined in accordance with ASCE 10 97 Design of
Latticed Steel Transmission Structures.
All horizontal and inclined members not greater 30 degrees were checked for 100kgs man
standing load at mid-span multiplied by 1.5 load factor.

All redundant members were checked and design to have a minimum capacity to the actual
force in the member.
Maximum slenderness ratios of all members in compression were limited to the following:
Megatro Power Distrubution Steel 230kv Steel Pylon Tower
Leg members 150
Other members 200
Redundant members 250

6.3 References
ASCE 10-97 Design of Latticed Steel Transmission Structures
NGCP General Design Criteria for 230kV Transmission Line
ACI Building Code requirements for Structural Concrete
PLS_Tower Manual 13.2 Version

7 steel tower types, line angles and effective loading span
Type Structure classification Deflection angle Wind span(m) Weight span (m) Uplift span (m)
conductor OPGW conductor OPGW
DS Tension 0~15° 400 1100 1600 500 800

DS tower features:
Tower Code Tower type Tower description Height (m) Basic body weight kgs
STR09 DS-suspension Basic body+9m body extension 30.5 11720

8 overload factors
Type of load Overload factor remarks
1 vertical load(under wind condition) 1.5 Applied on cond. I.II& Dead WT. of tower
2 vertical load(no wind, erection/ Maintenance ) 2.0 Applied on cond. III& Dead WT. of tower
3 transverse loads    
A due to wind 1.00 Applied on condition I, II and on longitudinal faces of poles
B due to angular tension in wires
Under wind condition
C wind on towers without wires
4 transverse load (no wind, erection /Maintenance) 2.0 Applied on condition III
5 longitudinal (no wind, erection /Maintenance) 2.0 Applied on condition III
6 other longitudinal loads 1.50 Applied on condition I and II
7 uplift load 1.50 Applied on condition I and II
8 uplift load 2.00 Applied on condition III

9 foundation
9.1 concrete type with embedded stub angle, for any type of tower, with or without body extension and any type of foundation shall be designed against maximum load considering all leg extensions.
9.2 for design of foundation in uplift, overload factor for dead weight of tower shall be one (1).

10 design loading conditions
Condition I              300KPH transverse wind(90°)direction
Condition la             similar to (I) but considering towers in uplift situations
Condition II             45° wind direction
Condition IIa            similar to (II) but considering towers in uplift situation
Condition III             erection and maintenance loading, no wind
Condition IIIa            similar to (III) but considering poles in uplift situations

11 tower data
Steel: high tensile steel ASTM A572 GR50 or BS EN10025-1993 grade steel S355JR or other equivalent standard
Steel members to be hot dipped galvanized to ASTM A123-1989
Bolts and nuts shall be conform to ASTM A325
Bolts and nuts to be hot dipped galvanized to ASTM F2329

12 Materials
STUB ANGLE : ASTM A572
SHEAR CONNECTOR : ASTM A572
CONNECTION BOLT : ASTM A325M
NUT : ASTM A563
WASHER : ASTM F436
GALVANIZING : ASTM 123 FOR ANGLE MEMBERS
ASTM 153 FOR BOLT, NUT & WASHER


Remark: above technical data only references for our client, we can design every type for our overseas clients.

MEGATRO is a full service engineering company with a global reputation for delivering excellence and innovation in power transmission, transformation, distribution, and telecommunications systems. Our MEGATRO provide and design this type 230kv double circuit MGP-230-DS-STR01 tower mainly for our overseas client. Since 2004, MEGATRO focus mainly international market and had export many kind of transmission structures to overseas clients. MEGATRO has been manufacturing lattice transmission tower & tapered steel tower for lighting, traffic control, communication and utility applications. MEGATRO pioneered the development of transmission tower, telecom tower, substation, and other steel structure and was also at the forefront in the design of Transmission tower.


Over 10 years of experience and innovation in engineering, designing and building tower has evolved MEGATRO into its current form:
  1. Full Turn-Key provider including site acquisition, engineering services, manufacturing,   field services-DAS, tech services, value added reseller and monitoring, maintenance and network ownership
  2. Specialize in developing supplying and building wireless and wired networks and in-building telecommunications systems, as well as energy infrastructure
  3. Single source from Design to System Integration
  4. Top quality, ISO 9001 registered
A complete selection of tower including self-support, lattice steel tower, mono tower and guyed tower, form custom-designed radar tower to broadcast tower and energy infrastructure. MEGATRO carries a variety of related products including fall protection, transmission lines, antennas, obstruction lights, and accessories, and other products if client need, MEGATRO also tailored product as per client condition.
MEGATRO mainly design all kinds of tower and posts for:
  1. Telecoms
  2. Power transmission
  3. TV and Radio Broadcast
  4. Roads and City Development
  5. Wind energy solution
  6. Steel structure and workshop

Our complete selection of tower includes:
  1. Self-supporting
  2. Monopole
  3. Guyed tower
  4. Custom-designed radar tower
  5. Broadcast tower
  6. Power transmission

MEGATRO also designs and manufactures tower related products including:
  1. Fall protection
  2. Antenna brackets
  3. Other accessories if needed by clients

Today, with over 10 years of experience and our commitment to excellence, MEGATRO remains an industry leader in the manufacture and design of steel tubular & angular & monopole structures for all Highway, Municipal, Custom, telecom, lighting and electric Utility applications. MEGATRO has a complete staff of professional engineering personnel trained in the PLS Tower program and three different manufacturing processes for producing steel tower, tower and other supports. We utilize the latest versions of PLS-CADD, PLS-TOWER, TOWER, AutoCAD and other CAD software.

The structure shall be designed according to load combinations given as per IEC 61936-1 and as illustrated below:
Normal loads
1 Dead weight load
2 Tension load
3 Erection load
4 wind load
 
Exceptional loads
1 Switching forces
2 short-circuit forces
3 Loss of conductor tension
4 Earthquake forces



Moreover, MEGATRO is fully equipped and qualified to carry out Design Engineering services which includes:
√ Overhead Transmission line steel tower & Telecom steel tower
   Basic Design and Analysis
√ Shop Erection Drawings
√ As-Built Drawings

MEGATRO performs in-house design activities specializing in electrical overhead transmission &telecom tower steel works, which include wind and earthquake loading, static analysis, stress analysis by finite element methods and fatigue. Our Engineering Department is boasting of highly qualified engineering who are conversant with international codes and standards. The work is carried out with extensive use of CAE/CAD via a large of computer network. The computer hardware & drafting software are liked to the CNC workshop equipment for downloading of information thereby eliminating error and saving valuable production time.

Besides, MEGATRO is one of the few manufactures who assemble a face of230kv double circuit MGP-230-DS-STR01 tower. This attention to quality may not be the cheapest process but it does insure every tower meets our high standards of quality. And it helps to reduce on-site construction cost due to mismatched assemblies. After fabrication all230kv double circuit MGP-230-DS-STR01 tower are delivered to the galvanizing facility to be Hot DIP Galvanized. Tower are processed through the facility by Caustic Cleaning, Pickling, and then Fluxing. These strict procedures insure years of maintenance free tower. MEGATRO'230kv double circuit MGP-230-DS-STR01 tower systems can accommodate a variety of cross-arm. MEGATRO also offers a wide variety of accessories and mounts.

Other information:
Availability size: Based on the customer's requirements.
Material: Chinese material or as per clients requirement
Steel grades
Tower legs: Chinese steel Q355B, which equivalent to ASTM A572 GR50
Other webs, bracing and not stress plate and angle steel: Chinese Q235B, which equivalent to ASTM A36
Plates: Chinese steel Q355B, which equivalent to ASTM A572 GR50
Bolts: Bolt quality shall be Chinese Class 6.8 and 8.8, as per our Chinese standard, or ISO 898 standard or ASTM A394 type 0,1,2,3 requirements

The anti-theft bolts shall be Huck bolt Fasteners or approved equivalent.  The fasteners shall be manufactured from high tensile steel A242 or equivalent and hot-dip galvanized in accordance with ASTM specification A153 and A394.

Fabrication standard: Chinese Standard or other standard which client accepted
A) Dimension and tolerance for angle are according to GB/T1591-1994, similar to EN 10056-1/2
B) Hot dip galvanization in accordance with GB/T 13912-2002, which similar to ASTM A 123
C) The welding will be performance in accordance with AWS D1.1 or CWB standard

D) All fastener galvanization conform to ASTM A153 requirements.

Package: Both parties discuss before delivery
Port of Loading: Qingdao Port
Lead Time: One month or based on the customer's needs ( for time being our capacity about 5000 tons one month, and can meet client requirements)
Minimum order: 1 set



General Fabrication Requirements
Here is general fabrication requirements for our transmission tower; however, both parties must discuss all drawings and confirm all shop drawings, technical specification, and which standard to conform.
Before mass production, we must received all signed approved shop drawings and technical documents from our client.

Our Fabrication shall be in strict accordance with detail Drawings prepared by the Contractor and approved by the Engineer.  Fabrication shall begin after the approval of the shop assembly and tests.
      
Shearing
      
Shearing and cutting shall be performed carefully and all portions of the work which will be exposed to view after completion shall be finished neatly.  Manually guided cutting torches shall not be used.

All material over 13 (or 12) mm thick shall be cold sawn or machine flame cut.
Cropping or shearing shall be allowed for material thickness of 13 mm or less.
Flame cutting of high yield steel shall be preceded by a slight preheat operation by passing the cutting flame over the part to be cut.
All flame-cut edges shall be ground clean.
      
Bending

Bending shall be carried out in such a manner as to avoid indentation and surface damage. All bending over 5o, or high yield steel, shall be performed while the material is hot.

Welding

No welding shall be done unless prior approval has been obtained from the Engineer.
Welding shall not be allowed at tower attachment points for conductor, shield-wire, insulators or associated assemblies or brackets.

Sub-punching

All holes in structural steel less than 10 mm thickness may be punched to full size unless otherwise noted on the approved Drawings.  Holes shown on the Drawings as drilled holes and all holes in structural steel 10 mm or more in thickness and tension members of cross-arms shall be drilled or sub-punched and reamed.

All holes shall be clean cut and without torn or ragged edges.  All burrs resulting from reaming or drilling shall be removed.  All holes shall be cylindrical and perpendicular to the member.

Where necessary to avoid distortion of the holes, holes close to the points of bends shall be made after bending.

Punching

For punching to full size, the diameter of the punch shall be 1.0 mm larger than the nominal diameter of the bolt, and the diameter of the die shall not be more than 1.5mm larger than the diameter of the punch. For sub-punching, the diameter of the punch shall be 4 mm smaller than the nominal diameter of the bolt, and the diameter of the die shall be not more than 2 mm larger than the diameter of the punch.  Sub-punching for reamed work shall be such that after reaming no punch surface shall appear in the periphery of the hole.

Hole Size

Where holes are reamed or drilled, the diameter of the finished hole shall be not greater than the nominal diameter of the bolt plus 1.0 mm.


Accuracy

All holes shall be spaced accurately in accordance with the Drawings and shall be located on the gauge lines.

The maximum allowable variation in hole spacing from that indicated on the Drawings for all bolt holes shall be 0.8 mm.

Fabrication Tolerances

A specification for tolerances shall be submitted for approval by the Engineer prior to commencement of fabrication.

Bolt List

A complete list of bolts showing their lengths and the members, which they are to connect shall be given on the erection diagrams.

Locking Devices

Locking devices for tower bolts will not be required, but point punching shall be performed.

Anti-theft Fasteners
      
Appropriate anti-theft fasteners for example Huck-bolting shall be applied on all the tower up to the level of anti-climbing devices, to prevent theft of tower members.
Piece Marks

All pieces shall be stamped before galvanizing with the piece marks shown on the erection Drawings, with the marking not less than 20 mm high placed in the same relative location on all pieces.  The marking shall be plainly visible after galvanizing.

Galvanizing

All material shall be hot-dip galvanized after fabrication in accordance with the latest revision of GB/T 13912-2002 or ASTM Specification A 123.

Material that has been rejected because of bare spots or other coating defects shall either be stripped and re-galvanized, or the uncoated areas shall be recoated by an approved method.

All plates and shapes which have been warped by the galvanizing process shall be straightened by being re-rolled or pressed.  The material shall not be hammered or otherwise straightened in a manner that will injure the protective coating.

Approval shall be secured from the Engineer if galvanizing is done outside of the Contractor's plant.

All galvanized steelwork shall be protected against white storage stain by using an approved dichromate solution treatment immediately following galvanizing.


APPLICABLE STANDARD AND CODES
All tower manufactured and design shall be generally in accordance with latest revision of the following standards except where specifically directed otherwise.
General
IEC 60826    -  Design criteria of overhead lines
IEC 60652    -  Loading tests on overhead line structures
ISO 1459    -  Metallic coatings - Protection against corrosion by Hot Dip Galvanizing
ISO 1461    -  Hot dip galvanized coatings on fabricated iron and steel articles
ISO 12944    -  Paint coatings, corrosion protection, and structural steelwork
ISO 898-1    -  Mechanical properties of fasteners. Part 1-Bolts, Screws and studs
ISO 630    -  Structural Steels - plates, wide flats, bars, sections and profiles
ISO 657    -  Hot rolled structural steel plates tolerances on dimensions and shape
ISO 7411    -  Hexagon Bolts for high strength structural bolting with large width across flats
ISO 657-5    -  Hot rolled Structural Steel Sections equal and unequal leg angles
ISO 7452    -  Hot rolled structural steel plates tolerances on dimensions and shape
BS EN 50341-1  - Overhead electrical lines exceeding AC 45kV -General Requirements
BS 8004    -  Code of Practice for Foundations
BS 8110    -  Structural use of concrete
ANSI10-97    - Design of latticed steel transmission structures
IEC 60050 (151)                         International Electro-technical Vocabulary
                                       Part 51 Electrical and Magnetic Devices
IEC 60050 (601)                      Chapter 601: Generation, transmission and distribution of electricity-General
IEC 60050 (601)                    Chapter 601: Generation, transmission and distribution of electricity-Operation
IEC 60059                              IEC standard current ratings
Chinese Standard
No Code DESCRIPTION
1 GB/T2694-2003 Power Transmission line Steel tower - Technical requirements for manufacturing
2 JGJ81-2002 Technical specification for welding for steel structure of building
3 GB9787-88 Measuring and allowable tolerance for hot-rolled equal angle
4 GB709-88 Measuring and allowable tolerance for hot-rolled plate and strip
5 GB/T699-1999 Quality Carbon Structural Steel
6 GB/T1591-1994 Low alloy high strength structural Steel
7 GB700-88 Carbon Structural Steel
8 GB222-84 Method of sampling steel for determination of chemical composition and permissible variations
9 GB/T228-2002 Method for Tensile testing of metals
10 GB/T232-1999 Method for Bending test of metals
11 GB/T5117-1995 Carbon Welding Rod
12 GB/T5118-1995 Low Alloy Welding Rod
13 GB/T8110-1995 Welding wires for gas shielding arc welding of carbon and low alloy steels
14 GB/T10045-2001 Carbon steel flux cored electrodes for arc welding
15 JB/T7949-1999 Weld outer dimensions for steel construction
16 GB50205-2001 Test Standard for Acceptance of Steel Structure
17 GB/T470-1997 Zinc Ingot
18 GB3098.1-2000 Mechanical properties of fasteners-Part 1:Bolts, screws and studs
19 GB3098.2-2000 Mechanical properties of fasteners-Part2: Nuts, and thread
20 GB3098.3-2000 Mechanical properties of fasteners-Part3: Fastening screw
21 GB/T5780-2000 Helical Bolts Grade C
22 GB/T41-2000 Helical Nuts Grade C
23 GB/T90-2002 Flat Washer Grade C
24 GB/T13912-2002 Metal Coating, Technical Requirement and Test Method for Hot-dip galvanized Metal Parts

American Standards:
Standard Description
ASTM A6/A6M Standard specification for general requirements for rolled structural steel bars, plates, and sheet piling.
ASTM - 6    -  General Requirements for delivery of Rolled Steel Plates, Shapes, sheet Piling Bars for  structural used
ASTM A36/A36-M-97a Standard specification for Carbon structural steel
ASTM A123 / A123M-02 Standard specification for Zinc (Hot-Dip Galvanized) Coatings on iron and steel products
ASTM A143 / A143M-03 Standard Practise for Safeguarding Against Embitterment of Hot-Dip Galvanized Structural Steel Products and Procedure for Detecting Embitterment
ASTM A153/ A153M-05 Standard specification for zinc coating (Hot-Dip) on iron and steel hardware
ASTM A - 194  -   Grade for bolt
ASTM A239 Standard practice for locating the thinnest spot in a zinc (Galvanized) Coating on Iron or Steel Articles
ASTM A242 Standard specification for High-Strength Low-Alloy Structural steel
ASTM A907 Standard Specification for Carbon Steel Bolts and Studs, 60000 PSI Tensile strength
ASTM A370-06 Standard Test Methods and Definitions for Mechanical Testing of Steel Products
ASTM A325 Standard Specification for structural bolts, steel, Heat treated 120/105 ksi minimum tensile strength
ASTM A-325 or A-354  -  Galvanized hexagonal head of  connection bolt
ASTM A325-97 Standard Specification for High-strength Bolts for structural steel Joints
ASTM A384 / A384M-02 Standard Practise for Safeguarding Against Warpage and Distortion During Hot-Dip Galvanizing of Steel Assemblies.
ASTM A394-93 Standard Specification for steel Transmission tower, Bolts, Zinc Coated and Bare
ASTMA - 563 -    Class and size of nuts
ASTMA - 572   - Chemical composition of steel
ASTM A572/A572-97c Standard specification for High-Strength Low-Alloy Columbium-Vanadium Structural steel
 ASTMA - 615  -   The anchor bolt material
ASTM A673 / A673M-07 Standard Specification for Sampling Procedure for Impact  Testing of Structural Steel
ASTM B201 Standard practice for testing Chromatic coating on Zinc and Cadmium surfaces
ASTM  E94-93 Standard Guide for Radiographic Testing
ASTM E 709-95 Standard Guide for Magnetic Particle Examination
ASCE Manual 72    -  Load testing a simple structure
ASCE 10-97 Standard Design of latticed steel transmission structures
AWS D1.1 American Welding Society D1,1/D1,1M structural Welding code- Steel
ANSI B-182-2 Bolts, nuts and washers dimensions

DIN VDE 0101                       -  Isokeraunic Level
VDE 0201                              - Climatic and environmental   conditions
CVDE 0210                           -  Minimum safety factors under    simultaneous working loads
ISO R898 Mechanical Properties of Fasteners
BS EN ISO 1461:1991 - High dip galvanized coatings on fabricated iron and steel articles. Specifications and standards
A) BS 5950: Welding Terms And Symbols
B) BS 729: Hot - Dip Galvanised Coating On Iron And Steel Articles
C) BS 2901: Filler Rods And Wires For Gas Shielded Arc Welding: Part 1 Ferritic Steels
D) BS 3692: ISO Metric Precision Hexagon Bolts, Screws And Nuts
E) BS 4360: Weldable Structural Steel
F ) BS 5135: Metal - Arc Welding Of Carbon And Carbon Manganese Steel
G) BS 5950: Part 1: Code Of Practice For Loading Latticed Tower & Masts
Part 2: Guide To The Background And Use Of Part 1"Code OF Practice For Loading"
Part 3: Strength Assessment of Members
H) DD 133 (1986): Code Of Practice For Loading Latticed Tower & Masts
I) BS 4592 (1987): Part 2: Specification For Expanded Metal Grating Panels
J) BS 4592 (1977): Code Of Practice For Protective Coating Of Iron And Steel Structure Against Corrosion
K) BS 4190: Bracing & Flanged Bolts
L) BS 4190: Rolled Steel sections, Flats & Plates

If any special requirement, we can design and discuss with client.

 