Megatro Solar Panel

Product Details
Condition: New
Certification: ISO
Application: Home, Industrial, Commercial
Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 14001, OHSAS/ OHSMS 18001
  • Megatro Solar Panel
  • Megatro Solar Panel
  • Megatro Solar Panel
  • Megatro Solar Panel
  • Megatro Solar Panel
  • Megatro Solar Panel
Find Similar Products

Basic Info.

Model NO.
MGP- solar panel
Specification
as Per Client, AS PER CLIENT
We Can Design Every Type
as Per Client Design and Data
Transport Package
Export Standard Package
Trademark
MEGATRO
Origin
Shandong, China
HS Code
73089000
Production Capacity
4000 Sets/Year

Product Description

MEGATRO Solar panel 
Megatro Solar Panel


Solar panel on building roof as a source of energy to generate electricity. A photovoltaic (PV) module is a packaged, connected assembly of typically 6x10 photovoltaic solar cells. Photovoltaic modules constitute the photovoltaic array of a photovoltaic system that generates and supplies solar electricity in commercial and residential applications.
Each module is rated by its DC output power under standard test conditions (STC), and typically ranges from 100 to 365 Watts (W). The efficiency of a module determines the area of a module given the same rated output - an 8% efficient 230 W module will have twice the area of a 16% efficient 230 W module. There are a few commercially available solar modules that exceed efficiency of 24%
A single solar module can produce only a limited amount of power; most installations contain multiple modules. A photovoltaic system typically includes an array of photovoltaic modules, an inverter, a battery pack for storage, interconnection wiring, and optionally a solar tracking mechanism.
The most common application of solar panels is solar water heating systems.
The price of solar power has continued to fall so that in many countries it is cheaper than ordinary fossil fuel electricity from the electricity grid, a phenomenon known as grid parity.
Here is the design strength of our Chinese tower bolts
2. MEGATRO SOLAR PANEL ON BUNLDIG ROOF typical configuration:
 
Lamp power Light / night Solar panel type/power Battery/ Voltage/ Capacity Configuration grade Average
peak radiation
Proper
slope angle
LED 30W 8 hours 100Wp
Mono / Poly
Lithium battery
12V 100Ah
Budget friendly type 3.81h 45°
10 hours 140Wp
Mono / Poly
Lithium battery
12V 100Ah
Medium type 4.57h 50°
12 hours 140Wp
Mono / Poly
Lithium battery
12V 120Ah
Abundant type 5.33h 20°
LED 42W 8 hours 120Wp
Mono / Poly
Lithium battery
12V 120Ah
Budget friendly type 3.81h 45°
10 hours 100Wp* 2pcs Mono / Poly Lithium battery
24V 100Ah
Medium type 4.57h 50°
12 hours 120Wp* 2pcs Mono / Poly Lithium battery
24V 110Ah
Abundant type 5.33h 20°
LED 56W 8 hours 150Wp
Mono / Poly
Lithium battery
12V 150Ah
Budget friendly type 3.81h 45°
10 hours 140Wp* 2pcs Mono / Poly Lithium battery
24V 120Ah
Medium type 4.57h 50°
12 hours 140Wp* 2pcs Mono / Poly Lithium battery
24V 150Ah
Abundant type 5.33h 20°
LED 64W 8 hours 100Wp* 2pcs Mono / Poly Lithium battery
24V 100Ah
Budget friendly type 3.81h 45°
10 hours 150Wp* 2pcs Mono / Poly Lithium battery
24V 120Ah
Medium type 4.57h 50°
12 hours 160Wp* 2pcs Mono / Poly Lithium battery
24V 150Ah
Abundant type 5.33h 20°

3.MEGATRO SOLAR PANEL ON BUNLDIG ROOFinstallation guideline: 
 
Lamp power LED 15W LED 20W LED 30W LED 42W LED 56W LED 64W
Light pole height 5-6m
(optional)
5-6m
(optional)
6-8m
(optional)
7-9m
(optional )
10m
(optional)
10m
( optional )
Proper road width 3 - 5m 3 - 5m 5 - 7m 5 - 8m 8 - 12m 8 - 12m
Interval recommended 15 ~ 25m 15 ~ 25m 15 ~ 25m 25 ~ 30m 30 ~ 35m 30 ~ 35m
Constantly
working days
5 - 7 days 5 - 7 days 5 - 7 days 5 - 7 days 5 - 7 days 5 - 7 days
Anti-winds force ≥40m/min ≥40m/min ≥40m/min ≥40m/min ≥40m/min ≥40m/min
Anti-seismic level > 8 magnitude > 8 magnitude > 8 magnitude > 8 magnitude > 8 magnitude > 8 magnitude
Working temperature -25 ~ +65 ºC -25 ~ +65 ºC -25 ~ +65 ºC -25 ~ +65 ºC -25 ~ +65 ºC -25 ~ +65ºC

Cards of quality. And it helps to reduce on-site construction cost due to mismatched assemblies. After fabrication all Solar panel on building roof
 are delivered to the galvanizing facility to be Hot DIP Galvanized. Towers are processed through the facility by Caustic Cleaning, Pickling, and then Fluxing. These strict procedures insure years of maintenance free towers. All finished surfaces shall be level and free of tears, burrs, clots and impurities.

Except otherwise specified elsewhere in the specification, the surface treatment and corrosion protection for all metal parts shall be in conformity with the latest revision of the standards listed below:
ASTM A 123 zinc (hot-dipped galvanized) coating on iron and steel products
DIN 55928 Protective painting of steel structure instructions
DIN 55945 Painting materials-Notions
DIN 18363 Paint work-Buildings
DIN 18364 Surface protection work for steel
DIN 53210 Determination of rust degree
DIN 55151 Determination of adhesion
ISO4628/3 Determination of rust penetration

MEGATRO'  Solar panel on building roof systems can accommodate a variety of cross-arm. MEGATRO also offers a wide variety of accessories and mounts.   
 

Other information:
Availability size: Based on the customer's requirements.
Material: Chinese material or as per clients requirement
Steel grades



 
Fabrication standard: Chinese Standard or other standard which client accepted
A) Dimension and tolerance for angle are according to GB/T1591-1994, similar to EN 10056-1/2
B) Hot dip galvanization in accordance with GB/T 13912-2002, which similar to ASTM A 123
C) The welding will be performance in accordance with AWS D1.1 or CWB standard

D) All fastener galvanization conform to ASTM A153 requirements.

Package: Both parties discuss before delivery
Port of Loading: Qingdao Port
Lead Time: One month or based on the customer's needs (For time being our capacity about 5000 tons one month, and can meet client requirements)
Minimum order: 1 set



General Fabrication Requirements
Here is general fabrication requirements for our transmission tower; however, both parties must discuss all drawings and confirm all shop drawings, technical specification, and which standard to conform.
Before mass production, we must received all signed approved shop drawings and technical documents from our client.





If any special requirement, we can design and discuss with client.


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier