Megatro Heavy Angle Single Circuit Tension 800kv Line Steel Power Tower

Product Details
Usage: Crossing Tower, Tension Tower, Angle Tower, Terminal Tower, Transposition Tower, Branching Tower, According to Client Requirements
Conductor Circuit: Single Circuit
Certification: ISO
Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 14001, OHSAS/ OHSMS 18001
  • Megatro Heavy Angle Single Circuit Tension 800kv Line Steel Power Tower
  • Megatro Heavy Angle Single Circuit Tension 800kv Line Steel Power Tower
Find Similar Products

Basic Info.

Model NO.
MG-PT800
Materials
Steel
Standard
According to Client Requirements
Style
According to Client Requirement
Structure
According to Client Requirement
Accessories 1
Power Fitting
Accessories 2
Conductor and Cable
Accessories 3
Earth Wire and Opgw
Accessories 4
Insulator
Accessories 5
Aviation Light
Accessories 6
Tower Earthing Kits and Template
Accessories 7
Razor Steel
Accessories 8
Anti-Climbing Devices
Accessories 9
Anti-Bird Devices
Accessories 10
Dangerous Plate
Accessories 11
Signal Plate
Accessories 12
Circuit and Phase Plate
Accessories 13
Fall Arrestor
Other Services1
Installation Guide
Other Services2
Engineering Cost and Project Budget
Transport Package
Export Package by Container or Bulk Cargo
Specification
as per drawings and client requirement
Trademark
MEGATRO
Origin
Shandong, China
HS Code
73082000
Production Capacity
50000 Tons/Year

Product Description

Megatro 800kv EHV single circuit Suspension Transmission tower
Megatro Heavy Angle Single Circuit Tension 800kv Line Steel Power Tower

This photo refers to our 800KV EHV single circuit Suspension Transmission tower, it is widely used in our Chinese market. Some of technical features of this tower as follow:

1 climate condition
Item Temperature (ºC) Wind speed (m/s) Ice thickness (mm)
Max. temperature 40 0 0
Mini. temperature -10 0 0
Ice thickness -5 10 10
Basic wind speed -5 27 0
Installation condition -5/-10 10 0
Annual temperature 15 0 0
Lightning overvoltage 15 10 0
Operation overvoltage 15 16 0
2 Technical specification of conductor and OPGW

Item
Conductor OPGW
JL/G3A-900/40 JLB20A-150

construction
AL 72×3.99 --
Steel(Al wrap steel ) 7×2.66 19×3.15

Cross-section
(mm2)
Al 900.26 37.02
Steel 38.90 111.05
Total 939.16 118.07
Diameter 39.90 15.75
Length mass (kg/km) 2818.1 989.4
Elastic module (MPa) 60800 147200
coefficient of linear expansion (1/ºC) 21.5×10-6 13.0×10-6
Rated broken (N) 203390 178570
3 tower design data
Tower
type
Nominal
Height
Scope (mm)
Horizontal
span
(m)
Vertical
Span
(m)
Angle
º
Nominal height tower weight Kg
ZC3 60 710 1000 0~3 45844
4 type and force of conductor and OPGW

Power
voltage

800KV
Conductor
type
6×JL/G3A-900/40 Max. operation
Tension force
(KN/phase)

463.729

Un-balance
Stress value(%)

10
OPGW
Type
JLB20A-150 Max. operation
Tension force
(KN/pc)
59.523 Un-balance
Stress value(%)

20
 
5 Operation data

Item
 
Horizontal
span
(m)
Vertical
Span
(m)
Representative
Span (m)
Angle
º
Height
(m)

KV
 
data 710 1000 400 0~3 60 0.65
6 loading data

Site condition
Normal operation condition Accident condition Installation
condition
Non-uniform
Ice condition
Basic wind speed Ice Mini.
temperature
Non-
broken
broken
Climate condition
(t/v/b)
-5/27/0 -5/10/10 -15/0/0 -5/0/10 -5/0/10 -5/10/0 -5/10/10
Horizontal loading conductor 116216 25035 0 0 0 12738 25035
Insulator
Power fitting
4745 561 0 0 0 468 561
Jump & string              
OPGW 9922 3513 0 0 0 945 3513
Vertical loading


 
conductor 198977 273717 182395 248834 248834 182395 228098
Insulator
Power fitting
19760 22264 29760 22264 22264 19760 22264
Jump & string              
OPGW 13313 28975 12828 26338 26338 12828 24143
Climate condition
(t/v/b)
-5/27/0 -5/10/10 -15/0/0 -5/0/10 -5/0/10 -5/10/0 -5/10/10
Stress  force conductor One side ---- ---- ---- ---- ---- 360783 ----
The other side ---- ---- ---- ---- ---- 360783 ----
Stress differences 0 0 0 0 115932 0 46373
OPGW One side ---- ---- ---- ---- ---- 51511 ----
The other side ---- ---- ---- ---- ---- 51511 ----
Stress differences         59509 0 11902
                     

7 Foundation distance size

Nominal
Height (m)
Foundation distance (mm) Anchor bolt
Front
distance
Side
distance
Type and quantity Distance /radius (mm) Material
39 8450 8450
4×M64

 
370
Chinese type
35 steel
42 9050 9050
45 9650 9650
48 10250 10250
51 10850 10850
54 11450 11450
57 12050 12050
60 12650 12650
63 13250 13250
66 13850 13850
69 14450 14450
72 15050 15050
75 15650 15650
78 16250 16250

8 Foundation force
 
Nominal
Height (m)
Tx Ty T Nx Ny N
39 185 269 1244 236 198 1572
42 184 268 1255 237 199 1601
45 189 273 1288 244 206 1645
48 192 275 1308 244 208 1681
54 201 185 1367 258 222 1763
60 201 184 1382 257 221 1805
66 220 195 1469 281 241 1935
72 239 219 1553 305 267 2060
78 240 219 1574 309 271 2112


9 Here is the design strength of Chinese tower steel
Steel material Anti-push, bending and press strength (N/mm2) Anti-shear strength
(N/mm2)
Grade Thickness or diameter (mm)
Q235
Steel
≤16 215 125
>16~40 205 120
>40~60 200 115
>60~100 190 110
Q345
Steel
≤16 310 180
>16~35 295 170
>35~50 265 155
>50~100 250 145
Q420
Steel
≤16 380 220
>16~35 360 210
>35~50 340 195
>50~100 325 185
Q460
Steel
≤16 415 240
>16~35 395 230
>35~50 380 220
>50~100 360 210

10 Here is the design strength of our Chinese tower bolts
Item Grade Anti-push strength (N/mm2) Anti-shear strength (N/mm2)
Fastener
for towers
4.8 200 170
5.8 240 210
6.8 300 240
8.8 400 300
Anchor
 bolts
Q235 160 /
Chinese 35 steel 190 /
Chinese 45 steel 215 /

Remark: above technical data only references for our client, we can design every type for our overseas clients.

MEGATRO is a full service engineering company with a global reputation for delivering excellence and innovation in power transmission, transformation, distribution, and telecommunications systems. Our MEGATRO provide and design this type 800KV EHV single circuit Suspension Transmission towermainly for our Chinese and overseas client. Since 2004, MEGATRO focus mainly international market and had export many kind of transmission structures to overseas clients. MEGATRO has been manufacturing lattice transmission tower & tapered steel poles for lighting, traffic control, communication and utility applications. MEGATRO pioneered the development of transmission tower, telecom tower, substation, and other steel structure and was also at the forefront in the design of Transmission tower.


Over 10 years of experience and innovation in engineering, designing and building towers has evolved MEGATRO into its current form:
  1. Full Turn-Key provider including site acquisition, engineering services, manufacturing,   field services-DAS, tech services, value added reseller and monitoring, maintenance and network ownership
  2. Specialize in developing supplying and building wireless and wired networks and in-building telecommunications systems, as well as energy infrastructure
  3. Single source from Design to System Integration
  4. Top quality, ISO 9001 registered
A complete selection of towers including self-support, lattice steel tower, monopoles and guyed towers, form custom-designed radar towers to broadcast towers and energy infrastructure. MEGATRO carries a variety of related products including fall protection, transmission lines, antennas, obstruction lights, and accessories, and other products if client need, MEGATRO also tailored product as per client condition.
MEGATRO mainly design all kinds of towers and posts for:
  1. Telecoms
  2. Power transmission
  3. TV and Radio Broadcast
  4. Roads and City Development
  5. Wind energy solution
  6. Steel structure and workshop

Our complete selection of towers includes:
  1. Self-supporting
  2. Monopoles
  3. Guyed towers
  4. Custom-designed radar towers
  5. Broadcast towers
  6. Power transmission

MEGATRO also designs and manufactures tower related products including:
  1. Fall protection
  2. Antenna brackets
  3. Other accessories if needed by clients

Today, with over 10 years of experience and our commitment to excellence, MEGATRO remains an industry leader in the manufacture and design of steel tubular & angular & monopole structures for all Highway, Municipal, Custom, telecom, lighting and electric Utility applications. MEGATRO has a complete staff of professional engineering personnel trained in the PLS Pole program and three different manufacturing processes for producing steel towers, poles and other supports. We utilize the latest versions of PLS-CADD, PLS-POLE, TOWER, AutoCAD and other CAD software.

The structure shall be designed according to load combinations given as per IEC 61936-1 and as illustrated below:
Normal loads
1 Dead weight load
2 Tension load
3 Erection load
4 wind load
 
Exceptional loads
1 Switching forces
2 short-circuit forces
3 Loss of conductor tension
4 Earthquake forces



Moreover, MEGATRO is fully equipped and qualified to carry out Design Engineering services which includes:
√ Overhead Transmission line steel tower & Telecom steel tower
   Basic Design and Analysis
√ Shop Erection Drawings
√ As-Built Drawings

MEGATRO performs in-house design activities specializing in electrical overhead transmission &telecom tower steel works, which include wind and earthquake loading, static analysis, stress analysis by finite element methods and fatigue. Our Engineering Department is boasting of highly qualified engineering who are conversant with international codes and standards. The work is carried out with extensive use of CAE/CAD via a large of computer network. The computer hardware & drafting software are liked to the CNC workshop equipment for downloading of information thereby eliminating error and saving valuable production time.

Besides, MEGATRO is one of the few manufactures who assemble a face of 800KV EHV single circuit Suspension Transmission tower. This attention to quality may not be the cheapest process but it does insure every tower meets our high standards of quality. And it helps to reduce on-site construction cost due to mismatched assemblies. After fabrication all 800KV EHV single circuit Suspension Transmission tower are delivered to the galvanizing facility to be Hot DIP Galvanized. Towers are processed through the facility by Caustic Cleaning, Pickling, and then Fluxing. These strict procedures insure years of maintenance free towers. All finished surfaces shall be level and free of tears, burrs, clots and impurities.

Except otherwise specified elsewhere in the specification, the surface treatment and corrosion protection for all metal parts shall be in conformity with the latest revision of the standards listed below:
ASTM A 123 zinc (hot-dipped galvanized) coating on iron and steel products
DIN 55928 Protective painting of steel structure instructions
DIN 55945 Painting materials-Notions
DIN 18363 Paint work-Buildings
DIN 18364 Surface protection work for steel
DIN 53210 Determination of rust degree
DIN 55151 Determination of adhesion
ISO4628/3 Determination of rust penetration

MEGATRO' 800KV EHV single circuit Suspension Transmission tower systems can accommodate a variety of cross-arm. MEGATRO also offers a wide variety of accessories and mounts.   
 

Other information:
Availability size: Based on the customer's requirements.
Material: Chinese material or as per clients requirement
Steel grades
Tower loading legs: Chinese steel Q420B, which equivalent to ASTM A572 GR60
Other webs, bracing and not stress plate and angle steel: Chinese Q235B, which equivalent to ASTM A36

Plates: Chinese steel Q345B, which equivalent to ASTM A572 GR50
Bolts: Bolt quality shall be Chinese Class 6.8 and 8.8, as per our Chinese standard, or ISO 898 standard or ASTM A394 type 0,1,2,3 requirements

The anti-theft bolts shall be Huckbolt Fasteners or approved equivalent.  The fasteners shall be manufactured from high tensile steel A242 or equivalent and hot-dip galvanized in accordance with ASTM specification A153 and A394.
 
Fabrication standard: Chinese Standard or other standard which client accepted
A) Dimension and tolerance for angle are according to GB/T1591-1994, similar to EN 10056-1/2
B) Hot dip galvanization in accordance with GB/T 13912-2002, which similar to ASTM A 123
C) The welding will be performance in accordance with AWS D1.1 or CWB standard

D) All fastener galvanization conform to ASTM A153 requirements.

Package: Both parties discuss before delivery
Port of Loading: Qingdao Port
Lead Time: One month or based on the customer's needs (For time being our capacity about 5000 tons one month, and can meet client requirements)
Minimum order: 1 set



General Fabrication Requirements
Here is general fabrication requirements for our transmission tower; however, both parties must discuss all drawings and confirm all shop drawings, technical specification, and which standard to conform.
Before mass production, we must received all signed approved shop drawings and technical documents from our client.

Our Fabrication shall be in strict accordance with detail Drawings prepared by the Contractor and approved by the Engineer.  Fabrication shall begin after the approval of the shop assembly and tests.
      
Shearing   
Shearing and cutting shall be performed carefully and all portions of the work which will be exposed to view after completion shall be finished neatly.  Manually guided cutting torches shall not be used.

All material over 13 (or 12) mm thick shall be cold sawn or machine flame cut.
Cropping or shearing shall be allowed for material thickness of 13 mm or less.
Flame cutting of high yield steel shall be preceded by a slight preheat operation by passing the cutting flame over the part to be cut.
All flame-cut edges shall be ground clean.
      
Bending
Bending shall be carried out in such a manner as to avoid indentation and surface damage. All bending over 5o, or high yield steel, shall be performed while the material is hot.

Welding
No welding shall be done unless prior approval has been obtained from the Engineer.
Welding shall not be allowed at tower attachment points for conductor, shield-wire, insulators or associated assemblies or brackets.

Sub-punching
All holes in structural steel less than 10 mm thickness may be punched to full size unless otherwise noted on the approved Drawings.  Holes shown on the Drawings as drilled holes and all holes in structural steel 10 mm or more in thickness and tension members of cross-arms shall be drilled or sub-punched and reamed.

All holes shall be clean cut and without torn or ragged edges.  All burrs resulting from reaming or drilling shall be removed.  All holes shall be cylindrical and perpendicular to the member.

Where necessary to avoid distortion of the holes, holes close to the points of bends shall be made after bending.

Punching
For punching to full size, the diameter of the punch shall be 1.0 mm larger than the nominal diameter of the bolt, and the diameter of the die shall not be more than 1.5mm larger than the diameter of the punch. For sub-punching, the diameter of the punch shall be 4 mm smaller than the nominal diameter of the bolt, and the diameter of the die shall be not more than 2 mm larger than the diameter of the punch.  Sub-punching for reamed work shall be such that after reaming no punch surface shall appear in the periphery of the hole.

Hole Size
Where holes are reamed or drilled, the diameter of the finished hole shall be not greater than the nominal diameter of the bolt plus 1.0 mm.

Accuracy
All holes shall be spaced accurately in accordance with the Drawings and shall be located on the gauge lines.
The maximum allowable variation in hole spacing from that indicated on the Drawings for all bolt holes shall be 0.8 mm.

Fabrication Tolerances
A specification for tolerances shall be submitted for approval by the Engineer prior to commencement of fabrication.

Bolt List
A complete list of bolts showing their lengths and the members, which they are to connect shall be given on the erection diagrams.

Step bolt:
Each  steel tower  shall be provided with step bolts on one of the legs for single circuit steel  tower  and  on  two  diagonally  opposite  legs  for  double  circuit  steel  tower  from approximately  2.5  meters  above  ground  level  to  the  cross  arm  and  from  thereon  to each  ground  wire  peak.  Step  bolts  shall  be  furnished  for  each  leg  extension  in  an amount of 25% of the step bolt holes. These bolts shall not be less than 16 mm or 3/4" diameter, double nut type, 18 cm or 7" long with 35 mm or 1 5/8"diameter, symmetrical head, two hexagon nuts and spring washers, spaced not more than 45 cm or 18" apart. Each bolt shall withstand without permanent deformation a vertical load of at least 137 kg applied at the bolt head. If any technical specification, we will discuss with our client and confirm before mass production.

Locking Devices
Locking devices for tower bolts will not be required, but point punching shall be performed.

Anti-theft Fasteners    
Appropriate anti-theft fasteners for example Huck-bolting shall be applied on all the towers up to the level of anti-climbing devices, to prevent theft of tower members.

Piece Marks
All pieces shall be stamped before galvanizing with the piece marks shown on the erection Drawings, with the marking not less than 20 mm high placed in the same relative location on all pieces.  The marking shall be plainly visible after galvanizing.

Galvanizing
All material shall be hot-dip galvanized after fabrication in accordance with the latest revision of GB/T 13912-2002 or ASTM Specification A 123.

Material that has been rejected because of bare spots or other coating defects shall either be stripped and re-galvanized, or the uncoated areas shall be recoated by an approved method.

All plates and shapes which have been warped by the galvanizing process shall be straightened by being re-rolled or pressed.  The material shall not be hammered or otherwise straightened in a manner that will injure the protective coating.

Approval shall be secured from the Engineer if galvanizing is done outside of the Contractor's plant.

All galvanized steelwork shall be protected against white storage stain by using an approved dichromate solution treatment immediately following galvanizing.

Shop Assembly and Inspection
All built-up assemblies shall be shop bolted complete with washers, after  galvanizing, and shipped as a unit. When specified in the Purchase Order,  MEGATRO shall completely assemble in the presence of Owner one (1) structure of each type before the first shipment of such structures. Any errors in the shop detail drawings or shop work shown by this assembly shall be immediately corrected. MEGATRO's proposal shall include the work required for these shop assemblies. Any material rejected by Owner for failure to conform with this specification or the Purchase Order shall be corrected or replaced by MEGATRO. The fact that material has been inspected, or Owner has waived the right to inspect any material, shall not prevent rejection of the material if it is found not to be in proper condition o r to have fabrication inaccuracies preventing proper assembly.

Design Calculations and Drawings
Our MEGATRO can perform complete design calculations, design drawings and shop detail drawings of each structure and submit checked calculations and drawings for Owner's review and distribution in the quantity, manner and time set forth in the Purchase Order. Our drawings consist of the following:

Design drawings showing structure dimensions, conductor clearance diagrams and schedule of member sizes, bolt sizes and material specifications.

Erection drawings showing each individual member with its identification  mark, location and position of outstanding leg of angles, with number, diameter and length of bolts for connection; and typical details to large scale where a number of members frame together.

Shop detail drawings showing all dimensions, draw for tension diagonals,  and all shearing punching, bevel cutting, grinding, bending and identification mark for each member.

A complete Bill of Material for each structure showing the number, kind, size, length, weight and identification mark for each member including all bolts.
(Remark: only PO confirmed, our MEGATRO can start shop drawings for client.)

Marking
All pieces shall be distinctively marked with erection marks clearly visible  after galvanizing, corresponding to those on the erection drawings. Steel tower  steel stamping dies, minimum 16 mm or 5/8" high, shall be used and special care shall be taken to see that all erection marks are  made  in  such  a  manner as not to be obliterated in transit, or in any way damage the galvanizing or impair the strength of the member.

In marking the members, each marking shall be prefixed by letters, which indicate the type of the steel tower. For members that are used in more than  one type of steel tower, all steel tower-type designations shall appear on the marking.

In addition, the members shall be marked with water -proof ink stencil 25 mm. or 1.0" high after galvanizing to facilitate in yarding the members and erecting the steel towers.

The diameter and the length of the bolt shall be marked on each bolt end so as to be visible after galvanizing.

An additional Contractor identification mark shall be stamped immediately in front of the piece identification marks. This Contractor identification mark  shall be submitted to Owner for acceptance and registration prior to first use.

Identification marks shall be located conspicuously to permit easy reading.   Marking of like pieces shall be identical in location, and pieces over 14 feet in length shall be marked at both ends.

Identification marks shall be applied as follows:
Before galvanizing stamp with 2.0mm deep, 15.0mm minimum height steel  die letters and numerals. After galvanizing neatly stencil a 6.0mm wide  straight line, to underline the identification marks, made with durable paint or ink that will adhere to the galvanized surface and remain legible.

All small items that are not adaptable to die marking and are not boxed shall be identified by either attaching die stamped steel tags or plastic tags with permanent markings. The tags shall be attached with non-corrosive wire.


Preparation for Shipping and Storage
To facilitate segregation of steel tower parts at the stockyard and to maximize the efficiency of erection, packaging of steel towers shall be as follows:
All steel tower parts, including stub angles, plates and steel tower parts member shall be color coded. The color code shall be painted on both ends of the steel tower parts for all angular members and around the edges for plates.   The color codes shall be as specified in the Technical Data Sheets. All stub angles shall be packaged per unit steel tower per type i.e., four (4) pieces per bundle.

All cleats including bolts and nuts with spring washers for stub angles shall be packaged per unit steel tower per type in wooden boxes with corresponding color code painted on all corners of the box.

All basic body steel towers shall be packaged per unit steel tower per type. Each package shall not exceed three (3) metric tons. The contents of each package per unit steel tower per type shall be identical for any succeeding  unit type. The numbering of each package shall indicate steel tower type (basic), steel tower number and number of pieces included in the package.


    Example:
MG -Basic/Steel tower No./Package No./Qty. in this package
MG -Basic/ 1 of 200/ 2/ 8

All bolts and nuts with spring washers shall be package in tin cans or wooden boxes per unit steel tower per type and numbered as follows:
    Example:
MG Bolts (Basic)/Steel tower No./Package No./Quantity

All plates and gussets for the basic steel tower shall be package in wooden boxes per unit steel tower per type and numbered as follows:
    Example:
MG Plates (Basic)/Steel tower No./Package No./Quantity

All body extension steel tower parts shall be package per unit steel tower per type. The weight of each package shall not be more than three (3) metric tons. The contents of each package per unit per steel tower shall be identical for any succeeding unit steel tower. The numbering of each package shall indicate  the steel tower type and extension steel tower number, and number of pieces included in the package.

    Example:
MG Body Ext./Steel tower No./Package No./Quantity
MG Body Ext./Steel tower No./Package No./Quantity
All bolts and nuts with washers and plates for the body extensions shall be  packaged in wooden boxes per unit steel tower per type and numbered as follows:
Example:
MG Plates & Bolts/Steel tower No./Package No./Quantity

All steel tower parts/members shall be marked as indicated in the steel tower  parts list. The markings shall be embossed, the size of which will be approved by the our client.

All package numbers for the steel tower shall be in label form. The size of the label shall be 5 cm x 10 cm. The label shall be waterproof and all letterings on the label shall be printed. This label shall be attached on every bundle of package. Each bundle or package shall have at least two (2) labels, each label is visible on each side of the bundle.

All bundle or packages for steel tower shall be properly strapped to avoid disintegration of the bundle when subjected to unnecessary impact. The strap shall be properly placed so that the breakage of one (1) or two (2) straps will not allow disintegration of the bundle or package.

Smaller pieces shall be bundled, with all the pieces in any bundle having the same mark.

All small pieces such as bolts and connections for ground wire and insulators shall be packed in boxes of not over 70 kg gross weight each. Bolts of different size or length shall be wrapped in separate sacks before boxing. Description, quantity, bolt size, and length shall be clearly marked on the outside of the sacks and boxes.

When specified in the Purchase Order, bundling and packaging shall be in lots for each individual structure. Boxes or other containers shall be clearly marked to indicate the type of steel tower for which the enclosed material is intended, and the quantity and marks or description of contents shall be shown on the outside.

Shipping shall be as specified by the Purchase Order and shall be in complete steel tower lots. All identifications shown on bundles, boxes or other containers  shall be included on Contractor's shipping and packaging lists.


APPLICABLE STANDARD AND CODES

All towers manufactured and design shall be generally in accordance with latest revision of the following standards except where specifically directed otherwise.
General
IEC 60826    -  Design criteria of overhead lines
IEC 60652    -  Loading tests on overhead line structures
ISO 1459    -  Metallic coatings - Protection against corrosion by Hot Dip Galvanizing
ISO 1461    -  Hot dip galvanized coatings on fabricated iron and steel articles
ISO 12944    -  Paint coatings, corrosion protection, and structural steelwork
ISO 898-1    -  Mechanical properties of fasteners. Part 1-Bolts, Screws and studs
ISO 630    -  Structural Steels - plates, wide flats, bars, sections and profiles
ISO 657    -  Hot rolled structural steel plates tolerances on dimensions and shape
ISO 7411    -  Hexagon Bolts for high strength structural bolting with large width across flats
ISO 657-5    -  Hot rolled Structural Steel Sections equal and unequal leg angles
ISO 7452    -  Hot rolled structural steel plates tolerances on dimensions and shape
BS EN 50341-1  - Overhead electrical lines exceeding AC 45kV -General Requirements
BS 8004    -  Code of Practice for Foundations
BS 8220    -  Structural use of concrete
ANSI10-97    - Design of latticed steel transmission structures
IEC 60050 (151)                         International Electro-technical Vocabulary
                                       Part 51 Electrical and Magnetic Devices
IEC 60050 (601)                      Chapter 601: Generation, transmission and distribution of electricity-General
IEC 60050 (601)                    Chapter 601: Generation, transmission and distribution of electricity-Operation
IEC 60059                              IEC standard current ratings
Chinese Standard
No Code DESCRIPTION
1 GB/T2694-2003 Power Transmission line Steel tower - Technical requirements for manufacturing
2 JGJ81-2002 Technical specification for welding for steel structure of building
3 GB9787-88 Measuring and allowable tolerance for hot-rolled equal angle
4 GB709-88 Measuring and allowable tolerance for hot-rolled plate and strip
5 GB/T699-1999 Quality Carbon Structural Steel
6 GB/T1591-1994 Low alloy high strength structural Steel
7 GB700-88 Carbon Structural Steel
8 GB222-84 Method of sampling steel for determination of chemical composition and permissible variations
9 GB/T228-2002 Method for Tensile testing of metals
10 GB/T232-1999 Method for Bending test of metals
11 GB/T5117-1995 Carbon Welding Rod
12 GB/T5118-1995 Low Alloy Welding Rod
13 GB/T8220-1995 Welding wires for gas shielding arc welding of carbon and low alloy steels
14 GB/T10045-2001 Carbon steel flux cored electrodes for arc welding
15 JB/T7949-1999 Weld outer dimensions for steel construction
16 GB50205-2001 Test Standard for Acceptance of Steel Structure
17 GB/T470-1997 Zinc Ingot
18 GB3098.1-2000 Mechanical properties of fasteners-Part 1:Bolts, screws and studs
19 GB3098.2-2000 Mechanical properties of fasteners-Part2: Nuts, and thread
20 GB3098.3-2000 Mechanical properties of fasteners-Part3: Fastening screw
21 GB/T5780-2000 Helical Bolts Grade C
22 GB/T41-2000 Helical Nuts Grade C
23 GB/T90-2002 Flat Washer Grade C
24 GB/T13912-2002 Metal Coating, Technical Requirement and Test Method for Hot-dip galvanized Metal Parts

American Standards:
Standard Description
ASTM A6/A6M Standard specification for general requirements for rolled structural steel bars, plates, and sheet piling.
ASTM - 6    -  General Requirements for delivery of Rolled Steel Plates, Shapes, sheet Piling Bars for  structural used
ASTM A36/A36-M-97a Standard specification for Carbon structural steel
ASTM A123 / A123M-02 Standard specification for Zinc (Hot-Dip Galvanized) Coatings on iron and steel products
ASTM A143 / A143M-03 Standard Practise for Safeguarding Against Embitterment of Hot-Dip Galvanized Structural Steel Products and Procedure for Detecting Embitterment
ASTM A153/ A153M-05 Standard specification for zinc coating (Hot-Dip) on iron and steel hardware
ASTM A - 194  -   Grade for bolt
ASTM A239 Standard practice for locating the thinnest spot in a zinc (Galvanized) Coating on Iron or Steel Articles
ASTM A242 Standard specification for High-Strength Low-Alloy Structural steel
ASTM A307 Standard Specification for Carbon Steel Bolts and Studs, 60000 PSI Tensile strength
ASTM A370-06 Standard Test Methods and Definitions for Mechanical Testing of Steel Products
ASTM A325 Standard Specification for structural bolts, steel, Heat treated 120/105 ksi minimum tensile strength
ASTM A-325 or A-354  -  Galvanized hexagonal head of  connection bolt
ASTM A325-97 Standard Specification for High-strength Bolts for structural steel Joints
ASTM A384 / A384M-02 Standard Practise for Safeguarding Against Warpage and Distortion During Hot-Dip Galvanizing of Steel Assemblies.
ASTM A394-93 Standard Specification for steel Transmission Tower, Bolts, Zinc Coated and Bare
ASTMA - 563 -    Class and size of nuts
ASTMA - 572   - Chemical composition of steel
ASTM A572/A572-97c Standard specification for High-Strength Low-Alloy Columbium-Vanadium Structural steel
 ASTMA - 615  -   The anchor bolt material
ASTM A673 / A673M-07 Standard Specification for Sampling Procedure for Impact  Testing of Structural Steel
ASTM B201 Standard practice for testing Chromatic coating on Zinc and Cadmium surfaces
ASTM  E94-93 Standard Guide for Radiographic Testing
ASTM E 709-95 Standard Guide for Magnetic Particle Examination
ASCE Manual 72    -  Load testing a simple structure
ASCE 10-97 Standard Design of latticed steel transmission structures
AWS D1.1 American Welding Society D1,1/D1,1M structural Welding code- Steel
ANSI B-182-2 Bolts, nuts and washers dimensions

DIN VDE 0101                       -  Isokeraunic Level
VDE 0201                              - Climatic and environmental   conditions
CVDE 0210                           -  Minimum safety factors under    simultaneous working loads
ISO R898 Mechanical Properties of Fasteners
BS EN ISO 1461:1991 - High dip galvanized coatings on fabricated iron and steel articles. Specifications and standards
A) BS 5950: Welding Terms And Symbols
B) BS 729: Hot - Dip Galvanised Coating On Iron And Steel Articles
C) BS 2901: Filler Rods And Wires For Gas Shielded Arc Welding: Part 1 Ferritic Steels
D) BS 3692: ISO Metric Precision Hexagon Bolts, Screws And Nuts
E) BS 4360: Weldable Structural Steel
F ) BS 5135: Metal - Arc Welding Of Carbon And Carbon Manganese Steel
G) BS 5950: Part 1: Code Of Practice For Loading Latticed Tower & Masts
Part 2: Guide To The Background And Use Of Part 1"Code OF Practice For Loading"
Part 3: Strength Assessment of Members
H) DD 133 (1986): Code Of Practice For Loading Latticed Tower & Masts
I) BS 4592 (1987): Part 2: Specification For Expanded Metal Grating Panels
J) BS 4592 (1977): Code Of Practice For Protective Coating Of Iron And Steel Structure Against Corrosion
K) BS 4190: Bracing & Flanged Bolts
L) BS 4190: Rolled Steel sections, Flats & Plates

If any special requirement, we can design and discuss with client.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier