Double Circuit Tangent Transmission Line Steel Tower

Product Details
Accessories 1: Anchor Bolts and Template
Transport Package: Export Standard Package
Specification: AS PER CLIENTS
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 14001, OHSAS/ OHSMS 18001
Find Similar Products

Basic Info.

Model NO.
MGP-DCT008
Trademark
MEGATRO
Origin
Shandong, China
HS Code
73082000
Production Capacity
50000 Tons/Year

Packaging & Delivery

Package Size
10000.00cm * 400.00cm * 400.00cm
Package Gross Weight
2600.000kg

Product Description

In power transmission line project, where the conductors are straight, a tangent tower is used. Tower structures are classified as tangent suspension and tangent strain. In a double circuit transmission line, tangent suspension and tangent strain tower often used. For suspension tower, the conductors are simply suspended from the tower, in this case, the tower is supposed to carry a downward force, and a lateral force, but not a longitudinal force. For a double-circuit transmission line, which has two circuits, both tubular and lattice steel towers can be designed so as to support two circuits of electrical current. Double-circuit tangent transmission towers hold the different conductors stacked atop one another, while in single-circuit towers the conductors are lined up horizontally.
Double Circuit Tangent Transmission Line Steel Tower

MEGATRO provide the double circuit tangent transmission lines tower for our esteemed clients. The Tower Line work involves Survey, check survey, and span calculations essential for tower extensions. Moreover, Tower designs and prototype approval is done. The towers are for 35KV, 66KV, 110 KV, 132 KV, 220 KV, 400 KV, 500KV, 750KV, and 800KV.

MEGATRO is one of the few manufactures who assemble a face of double circuit tangent transmission tower. This attention to quality may not be the cheapest process but it does insure every tower meets our high standards of quality. And it helps to reduce on-site construction cost due to mismatched assemblies.

After fabrication all double circuit tangent transmission tower are delivered to the galvanizing facility to be Hot DIP Galvanized. Towers are processed through the facility by Caustic Cleaning, Pickling, and then Fluxing. These strict procedures insure years of maintenance free towers.
MEGATRO's double circuit transmission tower systems can accommodate a variety of cross-arm. MEGATRO also offers a wide variety of accessories and mounts.
Availability size: Based on the customer's requirements.
Material: Chinese material or as per clients requirement
Package: Both parties discuss before delivery
Terms of Payment: L/C, T/T
Minimum Order Quantity: 10tons
Port of Loading: Qingdao Port
Lead Time: One month or based on the customer's needs
Performance Standard
Besides conform to the drawing and design, the materials and fabrication of tower components shall conform to the following standards
1. GB/T2694-2003 Transmission line tower - - Technical requirements for manufacturing
2. JGJ81-2002: Technical specification for welding for steel structure of building
3. GB9787-88: Measuring and allowable tolerance for hot-rolled equal angle
4. GB709-88: Measuring and allowable tolerance for hot-rolled plate and strip
5. GB/T699-1999: Quality Carbon Structural Steel
6. GB/T1591-1994: Low alloy high strength structural Steel
7. GB700-88: Carbon Structural Steel
8. GB222-84: Method of sampling steel for determination of chemical composition and permissible variations
9. GB/T228-2002: Method for Tensile testing of metals
10 GB/T232-1999: Method for Bending test of metals
11 GB/T5117-1995: Carbon Welding Rod
12 GB/T5118-1995: Low Alloy Welding Rod
13 GB/T8220-1995: Welding wires for gas shielding arc welding of carbon and low alloy steels
14 GB/T10045-2001: Carbon steel flux cored electrodes for arc welding
15 JB/T7949-1999: Weld outer dimensions for steel construction
16 GB50205-2001: Test Standard for Acceptance of Steel Structure
17 GB/T470-1997: Zinc Ingot
18 GB3098.1-2000: Mechanical properties of fasteners-Part 1: Bolts, screws and studs
19 GB3098.2-2000: Mechanical properties of fasteners-Part2: Nuts, and thread
20 GB3098.3-2000: Mechanical properties of fasteners-Part3: Fastening screw
21 GB/T5780-2000: Helical Bolts Grade C
22 GB/T41-2000: Helical Nuts Grade C
23 GB/T90-2002: Flat Washer Grade C
24 GB/T13912-2002: Metal Coating, Technical Requirement

We also adopt British, American and other international standard which client can accept.