Megatro 230kv Triple Circuit Dead End Transmission Tower (MGP-TD230)

Product Details
Usage: Flying Angle Tower, Crossing Tower, Tension Tower, Angle Tower, Terminal Tower, Transposition Tower, Branching Tower, as Per Client Requirements and Data
Conductor Circuit: as Per Client Requirements and Data
Certification: ISO
Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 14001, OHSAS/ OHSMS 18001
  • Megatro 230kv Triple Circuit Dead End Transmission Tower (MGP-TD230)
  • Megatro 230kv Triple Circuit Dead End Transmission Tower (MGP-TD230)
  • Megatro 230kv Triple Circuit Dead End Transmission Tower (MGP-TD230)
  • Megatro 230kv Triple Circuit Dead End Transmission Tower (MGP-TD230)
Find Similar Products

Basic Info.

Model NO.
MGP-TD230
Materials
Steel
Standard
as Per Client Requirements and Data
Style
as Per Client Requirements and Data
Structure
as Per Client Requirements and Data
We Design by Pls& Tower Software
as Per Client Requirements and Data
Accessories 1
Power Fitting
Accessories 2
Insulator
Accessories 3
Conductor and Cable
Accessories 4
Earth Wire and Opgw
Accessories 5
Aviation Light
Accessories 6
Tower Foundation and Anchor Bolt
Accessories 7
Tower Earthing Kits and Template
Accessories 8
Anti-Climbing Devices
Accessories 9
Anti-Bird Devices
Other Services 1
Installation Guide
Other Services 2
Engineering Consultant
Other Services 3
Project Budget
Transport Package
Export Standard Package
Specification
AS PER CLIENT REQUIREMENT
Trademark
MEGATRO
Origin
Shandong, China
HS Code
73082000
Production Capacity
50000 Tons/Year

Product Description

Megaro 230KV TRIPLE CIRCUIT DEAD END TRANSMISSION TOWER
MEGATRO provide 230-kV Triple Circuit Dead-end Transmission line tower, this structure is shielded by two overhead static wires and is a massively tall monument, rising over 120 feet. And we also can design them as per client different requirements.

This type dead-end tower uses horizontal strain insulators and occur at the endpoints of conductors, such endpoints are necessary when interfacing with other modes of power transmission and, due to the inflexibility of the conductors, when significantly altering the direction of the tower line. Dead-end towers are also employed at branch points as branch pylons. MEGATRO is one of the few manufactures who provide dead-end tower and assemble every tower section. This attention to quality may not be the cheapest process but it does insure every tower meets our high standards of quality. And it helps to reduce on-site construction cost due to mismatched assemblies.


After fabrication all 230kv dead end towers are delivered to the galvanizing facility to be Hot DIP Galvanized. Towers are processed through the facility by Caustic Cleaning, Pickling, and then Fluxing. These strict procedures insure years of maintenance free towers.
Availability size: Based on the customer's requirements.
Material: Chinese material or as per clients requirement
Package: Both parties discuss before delivery
Terms of Payment: L/C, T/T
Minimum Order Quantity: 1 ton
Port of Loading: Qingdao Port
Lead Time: One month or based on the customer's needs
Performance Standard
Besides conform to the drawing and design, the materials and fabrication of tower components shall conform to the Chinese Standard or other standard which clients can accept.

1. GB/T2694-2003 Transmission line tower - - Technical requirements for manufacturing
2. JGJ81-2002: Technical specification for welding for steel structure of building
3. GB9787-88: Measuring and allowable tolerance for hot-rolled equal angle
4. GB709-88: Measuring and allowable tolerance for hot-rolled plate and strip
5. GB/T699-1999: Quality Carbon Structural Steel
6. GB/T1591-1994: Low alloy high strength structural Steel
7. GB700-88: Carbon Structural Steel
8. GB222-84: Method of sampling steel for determination of chemical composition and permissible variations
9. GB/T228-2002: Method for Tensile testing of metals
10 GB/T232-1999: Method for Bending test of metals
11 GB/T5117-1995: Carbon Welding Rod
12 GB/T5118-1995: Low Alloy Welding Rod
13 GB/T8220-1995: Welding wires for gas shielding arc welding of carbon and low alloy steels
14 GB/T10045-2001: Carbon steel flux cored electrodes for arc welding
15 JB/T7949-1999: Weld outer dimensions for steel construction
16 GB50205-2001: Test Standard for Acceptance of Steel Structure
17 GB/T470-1997: Zinc Ingot
18 GB3098.1-2000: Mechanical properties of fasteners-Part 1: Bolts, screws and studs
19 GB3098.2-2000: Mechanical properties of fasteners-Part2: Nuts, and thread
20 GB3098.3-2000: Mechanical properties of fasteners-Part3: Fastening screw
21 GB/T5780-2000: Helical Bolts Grade C
22 GB/T41-2000: Helical Nuts Grade C
23 GB/T90-2002: Flat Washer Grade C
24 GB/T13912-2002: Metal Coating, Technical Requirement

We also adopt British, American and other international standard which client can accept.