Usage: | Crossing Tower, Tension Tower, Angle Tower, Terminal Tower, Transposition Tower, Branching Tower, According to Client′s Technical Specification |
---|---|
Conductor Circuit: | Double Circuit |
Certification: | ISO |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
SN | Type | Double circuit Self-Supporting lattice Steel Tension Tower with single earth wire |
1 | Nominal Voltage | 230kV |
2 | Number of circuits | Double |
3 | Conductor arrangement | Three Phase horizontal twin conductor |
5 | Temperature range | -15oC to 45oC |
Cross arm Height | 18m | |
6 | Aerial earth arrangement | Single earth peaks |
7 | Type of aerial earth | 1 x 7/2.64mm steel wire |
8 | Conductor type | ACSR "Zebra" conductor 61/3.31mm |
9 | Tower weight (kgs) | Approx.15312 |
10 | Anchorage | Stub anchorage complete with cleats |
11 | Deviation | 30 o -60o |
12 | Scope of supply | All tower members, bolts, nuts washers, anti-climb device, anti-bird guard, phase markers, number plates. |
13 | Maximum Wind | 45m/s |
14 | Wind span | 400m |
15 | Weight span | 620m |
16 | Drawings | Bolts, nuts, tower members, anti-climb device, name plate, dangerous plate, phase plate, number plate, and foundation |
17 | Bird Protection | Equipped with Anti - bird perch device on all phases |
18 | Anti -theft protection | Equipped with anti-theft bolts and anti-theft nuts from ground to anti0climb device |
19 | Design standard | ASCE Manual No -72, IS 802 (part I & part II)-1997, IS 5613 (part I & part II), transmission line manual (publication no -268 ) or BS EN 1993-3 |
20 | Type of Soil (Normal / Black cotton) | Blackish & dark grey silty CLAY with traces of fine sand. |
Remark: above technical data only references for our client, we can design every type for our overseas clients. |
1 | Line details - Circuit (SC) & KV. | SC, 400 KV | |
2 | Number of phases. | 3 | |
3 | Tower details | Wind span | Weight Span |
Tangent towers | 600m | 1000m | |
Normal span | 400m | ||
4 | Conductors Type ( ACSR/AAAC/etc) | AAAC, TWIN MOOSE Conductors. Sectional area of Aluminium: 528.5mm2 |
|
Conductor - Single/twin/quad/hexa | twin | ||
5 | Earth-wire | Single, 7/3.66 mm GS Earth wire | |
6 | Insulators. | 400 KV LONG ROD POLYMERIC | |
7 | Factor of safety. | 1.5 | |
8 | Ground clearances | 9500mm from ground to bottom conductor | |
9 | Minimum ground clearance | 6000mm | |
10 | Wind load on monopole | 89.6 kg/m2 | |
11 | Design details, and our 400KV monopole technical data as follow: . |
a) Angle monopole with tension insulator string. b) Also to be used for uplift force resulting from an uplift span up to 600m under broken wire conditions c) Also to be used for Anti Cascading Condition d) On the body of monopole, we provide strain plates of suitable dimensions under each cross-arm tip, for taking the hooks or D-shackles of the tension insulator strings. |
|
12 | Environmental condition of area (Temp). | Design Ambient Temperature 35 DegC | |
13 | Tower Height. | 21-24Meters(Subject to approval ) | |
14 | Design Code | ASCE Manual No -72, IS 802 (part I & part II)-1997, IS 5613 (part I & part II), transmission line manual (publication no -268 ) | |
15 | Type of Soil (Normal / Black cotton) | Blackish & dark grey silty CLAY with traces of fine sand. |
No | Code | DESCRIPTION |
1 | GB/T2694-2003 | Power Transmission line Steel tower - Technical requirements for manufacturing |
2 | JGJ81-2002 | Technical specification for welding for steel structure of building |
3 | GB9787-88 | Measuring and allowable tolerance for hot-rolled equal angle |
4 | GB709-88 | Measuring and allowable tolerance for hot-rolled plate and strip |
5 | GB/T699-1999 | Quality Carbon Structural Steel |
6 | GB/T1591-1994 | Low alloy high strength structural Steel |
7 | GB700-88 | Carbon Structural Steel |
8 | GB222-84 | Method of sampling steel for determination of chemical composition and permissible variations |
9 | GB/T228-2002 | Method for Tensile testing of metals |
10 | GB/T232-1999 | Method for Bending test of metals |
11 | GB/T5117-1995 | Carbon Welding Rod |
12 | GB/T5118-1995 | Low Alloy Welding Rod |
13 | GB/T8220-1995 | Welding wires for gas shielding arc welding of carbon and low alloy steels |
14 | GB/T10045-2001 | Carbon steel flux cored electrodes for arc welding |
15 | JB/T7949-1999 | Weld outer dimensions for steel construction |
16 | GB50205-2001 | Test Standard for Acceptance of Steel Structure |
17 | GB/T470-1997 | Zinc Ingot |
18 | GB3098.1-2000 | Mechanical properties of fasteners-Part 1:Bolts, screws and studs |
19 | GB3098.2-2000 | Mechanical properties of fasteners-Part2: Nuts, and thread |
20 | GB3098.3-2000 | Mechanical properties of fasteners-Part3: Fastening screw |
21 | GB/T5780-2000 | Helical Bolts Grade C |
22 | GB/T41-2000 | Helical Nuts Grade C |
23 | GB/T90-2002 | Flat Washer Grade C |
24 | GB/T13912-2002 | Metal Coating, Technical Requirement and Test Method for Hot-dip galvanized Metal Parts |
Standard | Description |
ASTM A6/A6M | Standard specification for general requirements for rolled structural steel bars, plates, and sheet piling. |
ASTM - 6 | - General Requirements for delivery of Rolled Steel Plates, Shapes, sheet Piling Bars for structural used |
ASTM A36/A36-M-97a | Standard specification for Carbon structural steel |
ASTM A123 / A123M-02 | Standard specification for Zinc (Hot-Dip Galvanized) Coatings on iron and steel products |
ASTM A143 / A143M-03 | Standard Practise for Safeguarding Against Embitterment of Hot-Dip Galvanized Structural Steel Products and Procedure for Detecting Embitterment |
ASTM A153/ A153M-05 | Standard specification for zinc coating (Hot-Dip) on iron and steel hardware |
ASTM A - 194 | - Grade for bolt |
ASTM A239 | Standard practice for locating the thinnest spot in a zinc (Galvanized) Coating on Iron or Steel Articles |
ASTM A242 | Standard specification for High-Strength Low-Alloy Structural steel |
ASTM A307 | Standard Specification for Carbon Steel Bolts and Studs, 60000 PSI Tensile strength |
ASTM A370-06 | Standard Test Methods and Definitions for Mechanical Testing of Steel Products |
ASTM A325 | Standard Specification for structural bolts, steel, Heat treated 120/105 ksi minimum tensile strength |
ASTM A-325 or A-354 | - Galvanized hexagonal head of connection bolt |
ASTM A325-97 | Standard Specification for High-strength Bolts for structural steel Joints |
ASTM A384 / A384M-02 | Standard Practise for Safeguarding Against Warpage and Distortion During Hot-Dip Galvanizing of Steel Assemblies. |
ASTM A394-93 | Standard Specification for steel Transmission Tower, Bolts, Zinc Coated and Bare |
ASTMA - 563 | - Class and size of nuts |
ASTMA - 572 | - Chemical composition of steel |
ASTM A572/A572-97c | Standard specification for High-Strength Low-Alloy Columbium-Vanadium Structural steel |
ASTMA - 615 | - The anchor bolt material |
ASTM A673 / A673M-07 | Standard Specification for Sampling Procedure for Impact Testing of Structural Steel |
ASTM B201 | Standard practice for testing Chromatic coating on Zinc and Cadmium surfaces |
ASTM E94-93 | Standard Guide for Radiographic Testing |
ASTM E 709-95 | Standard Guide for Magnetic Particle Examination |
ASCE Manual 72 | - Load testing a simple structure |
ASCE 10-97 | Standard Design of latticed steel transmission structures |
AWS D1.1 | American Welding Society D1,1/D1,1M structural Welding code- Steel |
ANSI B-182-2 | Bolts, nuts and washers dimensions |